Description
Class 2 Gas Filtration Cabinet CLASSIC RANGE
The cabins of ductless filtration of the Classic range are ideal for removing gaseous pollutants and/or solid particles/aerosols from your work area in a simple and effective, safe, efficient and cost-effective manner, protecting both the user and the environment.
This range is delivered unassembledIt can be placed in any laboratory without any problem (narrow passages, narrow or difficult to access stairs, etc.) and substantially reduce transportation costs.
All models in the Classic range use the newly developed and patented filtration system. (Patent of Invention) which guarantees the retention of gases, vapors and contaminating particles generated inside, thus constantly renewing the air in the laboratory. Its main advantages are:
Protection and respect for the environment
In addition to fully protecting the operator working inside the cabin, the toxic chemicals produced are not released to the outside but are retained in an activated carbon or zeolite filter.
Flexible
They can be used in areas where it is difficult to extract polluted air, such as in lower levels of buildings, and their wide range extends the possibilities of location, making it easy to replace them in case of changing needs.
Cost savings and fast location
No need to install exhaust ducts to the outside, so no additional costs or inconveniences are generated in a fully operational laboratory
Energy savings
Unlike traditional fume cupboards, they do not consume the air conditioning of the laboratory, which substantially reduces energy costs: the air sucked in is not expelled but recirculated back into the laboratory free of pollutants.
| Model | 670 | 870 | 990 | 1010 | 1200 | 1200XL |
| Internal dimensions (width/depth/height) | 576x563x630 | 776x566x720 | 976x566x720 | 976x566x920 | 1176x760x780 | 1176x967x1106 |
| External measurements (width/depth/height) | 600x600x937 | 800x600x1037 | 1000x600x1037 | 1000x600x1237 | 1200x800x1097 | 1200x1000x1422 |
| Filter columns | 1 | 1 | 1 | 1 | 1 | 1 |
| No. of filters | 1 a 2 | 1 a 2 | 1 a 2 | 1 a 2 | 1 a 2 | 1 a 2 |
| Fans | 1 | 1 | 1 | 1 | 1 | 1 |
| Average volume of air treated/hour | 112 m3/h | 160 m3/h | 160 m3/h | 160 m3/h | 160 m3/h | 160 m3/h |
| Average air velocity in facade | 0.50 m/s | 0.50 m/s | 0.50 m/s | 0.50 m/s | 0.50 m/s | 0.50 m/s |
| Cabin interior volume | 0.202 m3 | 0.316 m3 | 0.398 m3 | 0.508 m3 | 0.697 m3 | 1.258 m3 |
| Cabin air renewals/min. | 9.2 | 8.5 | 6.8 | 5.3 | 3.9 | 2.1 |
| Total electricity consumption | 57 W | 57 W | 60 W | 60 W | 60 W | 60 W |
| Voltage-Periods | 110-220 V / 50-60 Hz | 110-220 V / 50-60 Hz | 110-220 V / 50-60 Hz | 110-220 V / 50-60 Hz | 110-220 V / 50-60 Hz | 110-220 V / 50-60 Hz |
| LED illumination level | 1300 lx / LED 18 W | 1100 lx / LED 18 W | 1100 lx / LED 18 W | 823 lx / LED 18 W | 800 lx / LED 18 W | 800 lx / LED 18 W |
| UV lamp | - | - | - | - | - | - |
| Noise level | 55 dB ± 3 dB | 55 dB ± 3 dB | 58 dB ± 3 dB | 58 dB ± 3 dB | 58 dB ± 3 dB | 58 dB ± 3 dB |
| Weight | 58 Kg | 77 Kg | 90 Kg | 95 Kg | 118 Kg | 123 Kg |
| Box volume | 0.33 m3 | 0.43 m3 | 0.52 m3 | 0.52 m3 | 0.65 m3 | 0.65 m3 |